Operating in Winter Conditions
Published: Updated:
This resource provides an overview of the most common high-risk conditions for winter sUAS operations, along with risk-mitigating strategies that can be integrated into organizational standard operating procedures (SOPs).
While planning Dock-based (Remote Flight Deck) operations or Controller-flown flights, consider how the flight system will perform in the environment by evaluating system limitations against environmental data. Situational awareness must be maintained at all times to ensure safe, reliable operations, including while autonomous features are engaged.
Always defer to your organization’s policies for winter operations and your local weather authority for up-to-date readings and hourly METARs (Meteorological Aerodome Reports) for local conditions.
For questions or concerns related to system performance, please contact support@skydio.com.
Dock for X10 Flight System Limitations
Key Terms
Operational Limitations: Refers to conditions in which the flight system may be operated.
Standby Limitations: Refers to conditions in which the flight system maintains limited operational capacity.
Environmental Limitations
Cold Temperatures
200-240V (20A) power supply must be run to the Dock for X10 in environments that experience freezing or sub-freezing temperatures ( ≤ 32°F / 0°C).
System limitations apply only when adequate power supply is provided.
Operational Limit: -4°F (-20°C)
Standby Limit: -40°F (-40°C)
Wind
Operational Wind-bearing Limit of the X10 Drone: 28 mph (45 km/h)
Wind-bearing Limit of the Dock for X10 when anchored to a permanent structure: 160 mph (257 km/h)
Wind-bearing Limit of the Dock for X10 when mounted on Skydio Dock Feet: 80 mph (128 km/h)
Wind-bearing Limit of the Dock for X10 mounted on included Stand: 40 mph (64 km/h)
Skydio X10 Controller-Based System Limitations
Environmental Limitations
Temperature
When operating in freezing or sub-freezing temperatures (32°F / 0°C), battery temperature of must be maintained during transport and prior to launching the aircraft. Ideal storage and transport temperature for lithium ion batteries is standard room temperature (59°F to 77°F / 15°C to 25°C).
Prior to operating the aircraft in conditions ≤ 32°F, pre-warm the lithium ion batteries in accordance with the guidance in the Best Practices section below.
Operational limit: -4°F (-20°C); when pre-warming procedures are conducted
Wind
Operational Limit (including gusts): 28 mph (45 km/h)
Precipitation
Skydio X10 (IP55) supports light to moderate precipitation
Avoid heavy rain, snow, or mixed precipitation
Be aware of residual environmental moisture after precipitation. Flying near wet vegetation, dripping trees, or surfaces can introduce water droplets onto cameras and sensors, even when active precipitation has stopped.
Launching or piloting the drone in icing conditions is not advised. Before flight, review local weather forecasts and trends for temperatures near or below freezing and indications of moisture such as rain, fog, low cloud cover, freezing drizzle, or snow. Use Dock weather data and cameras to confirm on-site conditions before launching.
Low Visibility
Maintain 3 statute miles (4.8 km) visibility or greater
Conditions can change quickly in winter; reassess if visibility, moisture, or temperatures shift during operations. Moisture on cameras or sensors, weather from active precipitation or residual environmental moisture, can degrade visual performance and affect flight behavior.
Best Practices for Dock-Based Remote Operations
Keep the Dock powered continuously during winter to maintain heating, battery warming, and system readiness. Extended power loss in cold conditions can reduce thermal protection and require additional time to restore normal operations.
Clear snow and ice from roof, hinge, and landing zone
Avoid opening Dock in winds above 40 mph (64.4 km/h)
Monitor Dock weather data and watch for gusts near terrain or structures
If Dock power is lost for an extended period in cold weather (such as during freezing or near-freezing conditions where heating is required), remove the drone and battery and allow at least 60 minutes of warm-up after power is restored. This warm-up period allows the Dock, aircraft, and battery to return to stable operating temperatures. Skipping this step may result in delayed flight readiness or reduced system performance until thermal conditions are fully restored.
Icing Detection Alerts
The Dock for X10 Flight System monitors inflight performance for signs of reduced lift or increased drag that may indicate ice forming on the drone. If icing is detected, Remote Pilots will receive an alert, enabling early corrective action before flight performance degrades.
Icing alerts may appear in temperatures up to 46°F (8°C)
When this alert appears, Remote Pilots should safely and promptly land the aircraft and discontinue flight operations until conditions improve
Winter Preflight Checklist (Recommended)
Many of the key considerations for successful winter flying are captured in this checklist. We recommend using it as a primary decision aid before each flight, alongside your organization’s operational guidelines and situational judgment.
Check local weather forecasts to assess expected wind speeds and gusts, temperatures near or below freezing, precipitation type and intensity, and the potential for icing conditions, then review Dock weather station data and cameras to confirm on-site conditions and visibility at the launch location.
Confirm launch and landing areas are clear using Dock cameras
Inspect aircraft (verify there is no ice, snow, or frost visible on the aircraft pre-launch; cameras and sensors are clean and not obscured by moisture, or debris)
Verify battery is fully charged and pre‑warmed if below 32°F (0°C)
Confirm system health (GPS, Remote ID, ADS‑B if applicable)
Best Practices for Skydio X10 Controller-Based Operations
Battery Warming
Cold temperatures can reduce available flight time. Skydio X10 batteries include a built‑in self‑warming feature to support operations down to ‑4°F (‑20°C).
Required below 32°F (0°C)
Battery must be ≥30% charged to self‑warm
Fully charged batteries are recommended
How to warm:
Outside the drone: Triple‑tap battery power button
Inside the drone: Insert battery and power on (automatic warming)
Icing
Icing can occur when moisture contacts the aircraft at 32°F (0°C) or colder.
If ice buildup, degraded video, or reduced performance is observed, land promptly
Fine powder snow may reduce visibility—land if conditions degrade
Skydio X10 also provides icing detection alerts during Controller-flown flights. Alerts may appear in temperatures up to 46°F (8°C); when one appears, safely and promptly land and discontinue flight operations until conditions improve.
Moisture-related sensor occlusion can also occur outside of icing conditions and may degrade visual performance or flight behavior if cameras or sensors become obstructed.
Postflight
After winter flights:
Inspect for ice, frost, or damage
Drain and dry aircraft if flown in precipitation
Check propellers, cameras, and battery condition
When to Pause Operations
Use the following scenarios as indicators to reassess conditions and determine whether proceeding aligns with your mission objectives and operating standards.
Pausing or delaying a flight in the following conditions helps protect mission success and system reliability:
Temperatures outside the recommended range
Winds above 28 mph (45 km/h)
Heavy precipitation or poor visibility
Icing conditions
Active system warnings or alerts
Additional Resources
Questions? Skydio Support is available to help you plan safe and successful winter operations.
Skydio Inc., A0620
Was this article helpful?